Files
Labview-Program/Acoustics Test/Mic-IQC/PDM_Mic_Test.cfg

79 lines
1.8 KiB
INI
Raw Normal View History

2025-09-09 15:08:42 +08:00
[main Config]
debug = "true"
mic test = "false"
corr to ref mic = "false"
getsn = "ddputil"
GS List = ""
[hardware config]
2025-09-29 08:33:41 +08:00
autostart = "COM8"
2025-09-09 15:08:42 +08:00
relay control = "com4"
mic vdd = ""
2026-01-05 14:47:01 +08:00
soundcard output = "Speakers (USB PnP Audio Device)"
2025-09-29 08:33:41 +08:00
soundcard input(max 4) = "Microphone (USB Advanced Audio Device)"
2025-09-09 15:08:42 +08:00
[Signal Config]
2026-01-05 14:47:01 +08:00
AddHead? = "false"
2025-09-09 15:08:42 +08:00
Head Freq = "1000"
2026-01-05 14:47:01 +08:00
amplitude = "0.8"
2025-09-09 15:08:42 +08:00
Sampling Rate = "48000"
2025-09-29 08:33:41 +08:00
StarFreq = "22400"
StopFreq = "50"
2025-09-09 15:08:42 +08:00
Min Cycles = "12"
Octave = "12"
Min Duration = "0.01"
[Play&Record Config]
playChannel(1:L 2:R) = "1"
delay before play(ms) = "200"
delay after play(ms) = "100"
2025-09-29 08:33:41 +08:00
recordChannels = "1"
2025-09-09 15:08:42 +08:00
add recording time(s) = "0.2"
save waveform = "false"
waveform path = "C:\Sonos\Pallas FA Test\PallasPlus_ChirpTest\waveform"
[Ref Mic Setting]
Ref Mic = "false"
2026-01-05 14:47:01 +08:00
soundcard input = "Microphone(USB PnP Audio Device)"
2025-09-09 15:08:42 +08:00
recordChannels(1:L 2:R) = "1"
[Analyze Config]
maximum harmonic = "5"
sensitivity start Hz = "1000"
sensitivity end Hz = "1000"
Smoothing Width = "1/3"
Units = "dBSPL"
Windowing = "false"
Start Freq = "100"
Stop Freq = "20000"
[Delta config]
2026-01-05 14:47:01 +08:00
Operand A = "FR - Smoothed DUT Mic1;Value - Sens DUT Mic1"
Operand B = "FR - Smoothed GS Mic1;Value - Sens GS Mic1"
Output = "FR - Delta Smoothed DUT Mic1;Value - Delta Sens DUT Mic1"
2025-09-09 15:08:42 +08:00
[Curve Limits]
2025-09-29 08:33:41 +08:00
Name = "Lim - Delta Smoothed DUT Mic1"
Upper Limit = "100,1.5,5000,1.5,5001,1.5,10000,1.5,15000,1.5,20000,2"
Lower Limit = "100,-1.5,5000,-1.5,5001,-1.5,10000,-1.5,15000,-1.5,20000,-2"
2025-09-09 15:08:42 +08:00
[single limits]
2026-01-05 14:47:01 +08:00
Name = "Lim - Sens DUT Mic1"
Upper Limit = "10"
Lower Limit = "-10"
2025-09-09 15:08:42 +08:00
[autosave]
StationNum = "MicTest001"
ProductName = "RH_PDM_Mic"
TestName = "Mic IQC"
2026-01-05 14:47:01 +08:00
json Path = "D:\IDU_MFG_OUTGOING"
2025-09-09 15:08:42 +08:00
backup = "true"
TMS = "false"
GSSN Path = ""
MES Path = ""
[DUT Play Config]
DUT IP = ""
set mode = ""
Vol = "60"
Wave Filename = ""