Files
Labview-Program/Acoustics Test/Pallas Plus Chirp Test V2/Config.ini

62 lines
1.6 KiB
INI
Raw Normal View History

2025-09-09 15:08:42 +08:00
[main Config]
debug = "true"
mic test = "false"
corr to ref mic = "false"
getsn = "ddputil"
GS List = ""
[Signal Config]
AddHead? = "true"
Head Freq = "5000"
amplitude = "2"
Sampling Rate = "44100"
StarFreq = "20000"
StopFreq = "1000"
Min Cycles = "12"
Octave = "24"
Min Duration = "0.02"
[Play&Record Config]
config soundcard = "true"
soundcard Output = "WDM/MME,Speakers (USB PnP Audio Device)"
soundcard input = "WDM/MME,Microphone (USB PnP Audio Device)"
playChannel(1:L 2:R) = "2"
delay before play(ms) = "200"
delay after play(ms) = "100"
recordChannels = "1"
add recording time(s) = "0.2"
save waveform = "false"
waveform path = "C:\Sonos\Pallas FA Test\PallasPlus_ChirpTest\waveform"
dut play = "true"
[Ref Mic Setting]
Ref Mic = "false"
soundcard input = "WDM/MME,Microphone Array (USB PnP Audio Device)"
recordChannels(1:L 2:R) = "1"
[Analyze Config]
maximum harmonic = "5"
sensitivity range= "1000,5000"
Units = "dBSPL"
Smoothing = "1 Octave,1000,15000;1/3 Octave,15000,20000"
[Limits]
Name = "Lim - Delta Smoothed DUT; Lim - THD DUT"
Upper Limit = "1000,4.5,5000,4.5,5001,3,10000,3,15000,3.5,20000,3.5;1000,2.5,1600,2.5,2000,2.5,3000,1,5000,1,8000,1,10000,0.3,20000,0.3"
Lower Limit = "1000,-4.5,5000,-4.5,5001,-3,10000,-3,15000,-3.5,20000,-3.5;1000,0,1600,0,2000,0,3000,0,5000,0,8000,0,10000,0,20000,0"
[autosave]
StationNum = "SPL001"
ProductName = "PALLAS PLUS"
TestName = "Chirp Test"
json Path = "D:\IDU_MFG_OUTGOING"
backup = "true"
TMS = "false"
GSSN Path = ""
MES Path = ""
[DUT Play Config]
DUT IP = "169.254.1.1"
set mode = ""
Vol = "60"
Wave Filename = "Stimulus44k.wav"