<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"ALPINE"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"False"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"AMP"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Alpine"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Alpine"
ModelSuffix,"-1-25.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,49 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"BEACON"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want certs installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
BlueToothSupport,"True"
#Paramount and Beacon refuse to blink when stopped in U-Boot after Upgrade
BlinkingLedMsg,"False"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Beacon"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Beacon"
ModelSuffix,"-1-20.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,45 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"BOOTLEG"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want certs installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"7828CA0 7828CA1"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Bootleg"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Bootleg"
ModelSuffix,"-1-21.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,31 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"Chaplin"
TestName,"DOWNGRADE"
TestNameForLog,"DOWNGRADE"
#Station can be Downgrade to Diag or Production to Production Upgrade
ProductionUpgrade,"false"
RmaDowngrade,"true"
#Waiting for the White LED to flash for P2P is maybe quicker but possibly not
#as sure as waiting for the succesful ping. The white led timer can be tweaked
#for maximum efficiency
WaitForPing,"False"
WhiteLedTimer,35
#Uncomment out the appropriate paths depending on the Apache installation
DiagServerAddr,"http://169.254.2.2/DiagFirmware/"
ProductionServerAddr,"http://169.254.2.2/Prod2ProdUpgrade/"
DiagUpdPath,"C:\Apache24\htdocs\DiagFirmware"
#DiagUpdPath,"C:\program files\apache group\apache2\htdocs\DiagFirmware"
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\Prod2ProdUpgrade"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\Prod2ProdUpgrade"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,56 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"ELREY"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA AUDIOSA FA1"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
BlueToothSupport,"True"
#MfgNumItems,8
MfgNumItems,6
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"PWR"
MfgItems[3],"RADIO"
MfgItems[4],"CCI"
MfgItems[5],"CBI"
#MfgItems[6],"WIFIMAC"
#MfgItems[7],"WIFITYPE"
#Override forspecialty wipes. In Elrey P2A, we want wifi info left in jffs
#WipeCommand,"operation/wipejffs?test=rpt_elrey"
WhiteLedWait,55
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"949F3EC 949F3ED"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\ElRey"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\ElRey"
ModelSuffix,"-1-23.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,39 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"ENCORE"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
MfgNumItems,0
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"5CAAFD0"
RmaUpgrade,"True"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
#DestinationPort,"8443"
#CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Encore"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Encore"
ModelSuffix,"-1-13.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,50 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"HIDEOUT"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"True"
BlueToothSupport,"True"
SeriesID,"A100"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"RCA"
MfgItems[3],"PWR"
#MfgItems[4],"WIFIMAC"
#MfgItems[5],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"347E5C0"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Hideout"
ProductionUpdPath,"C:\Program Files\Apache Group\Apache2\htdocs\ShipFirmware\Hideout"
ModelSuffix,"-1-24.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,48 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"PARAMOUNT"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"False"
#Paramount and Beacon refuse to blink when stopped in U-Boot after Upgrade
BlinkingLedMsg,"False"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"AMP"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"949F3EB"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Paramount"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Paramount"
ModelSuffix,"-1-22.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,55 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"SOLBASE"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"False"
#Early builds may not want certs installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
#MfgNumItems,8
MfgNumItems,6
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"PWR"
MfgItems[3],"RADIO"
MfgItems[4],"CCI"
MfgItems[5],"CBI"
#MfgItems[6],"WIFIMAC"
#MfgItems[7],"WIFITYPE"
#Override forspecialty wipes. In Elrey P2A, we want wifi info left in jffs
#WipeCommand,"operation/wipejffs?test=rpt_elrey"
WhiteLedWait,35
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
DestinationPort,"443"
CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.253.0.3"
#IAC
#DestinationPort,"8443"
#CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Solbase"
#ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Solbase"
ModelSuffix,"-1-14.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,48 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"Tupelo"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"True"
BlueToothSupport,"True"
SeriesID,"A100"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Tupelo"
ProductionUpdPath,"C:\Program Files\Apache Group\Apache2\htdocs\ShipFirmware\Tupelo"
ModelSuffix,"-1-26.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,49 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"HIDEOUT"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
Not yet a working option
GetMacFromFIS,"False"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
BlueToothSupport,"True"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"RCA"
MfgItems[3],"PWR"
#MfgItems[4],"WIFIMAC"
#MfgItems[5],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"347E5C0"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Hideout"
ProductionUpdPath,"C:\Program Files\Apache Group\Apache2\htdocs\ShipFirmware\Hideout"
ModelSuffix,"-1-24.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,50 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"HIDEOUT"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"True"
BlueToothSupport,"True"
SeriesID,"A100"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"RCA"
MfgItems[3],"PWR"
#MfgItems[4],"WIFIMAC"
#MfgItems[5],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"347E5C0"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Hideout"
ProductionUpdPath,"C:\Program Files\Apache Group\Apache2\htdocs\ShipFirmware\Hideout"
ModelSuffix,"-1-24.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,47 @@
<Step Name>,Comp,Limits.High,Limits.Low
,,,
<Locals>,Variable Value,,
,,,
<FileGlobals>,Variable Value,,
ProductName,HIDEOUT,,
TestName,UPGRADE,,
TestNameForLog,UPGRADE,,
PreviousTestsRequired,CPUSA PREBURNIN,,
SetUpForNextStation,1,,
,,,
#Not yet a working option,,,
GetMacFromFIS,TRUE,,
,,,
#Early builds may not want cewrts installed- set to False, in that case,,
IncludeCertLogic,TRUE,,
SeriesIdSupport,FALSE,,
BlueToothSupport,TRUE,,
,,,
MfgNumItems,4,,
MfgItems[0],CPU,,
MfgItems[1],AMP,,
MfgItems[2],WIFIMAC,,
MfgItems[3],WIFITYPE,,
,,,
#Append the OUI+product range to the next string to add new serial number range,,,
SerialNumberFormats,,,
#Uncomment the Sonos or IAC settings, depending on where you are running. These are,,
#Cert Server values,,,
#Sonos,,,
#DestinationPort,443,,
#CertServer,https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx,,
#DestinationAddress,10.253.0.3,,
#IAC,,,
DestinationPort,8443,,
CertServer,https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx,,
DestinationAddress,10.159.248.10,,
,,,
#uncomment out the appropriate path depending on the Apache installation,,,
#ProductionUpdPath,C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Hideout,,
ProductionUpdPath,C:\program files\apache group\apache2\htdocs\ShipFirmware\Hideout,,
ModelSuffix,-1-24.upd,,
,,,
,,,
<StationGlobals>,Variable Value,,
ProductionDataFolder,C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING,,
EngineeringDataFolder,C:\Sonos Engineering Data,,
1 <Step Name> Comp Limits.High Limits.Low
2
3 <Locals> Variable Value
4
5 <FileGlobals> Variable Value
6 ProductName HIDEOUT
7 TestName UPGRADE
8 TestNameForLog UPGRADE
9 PreviousTestsRequired CPUSA PREBURNIN
10 SetUpForNextStation 1
11
12 #Not yet a working option
13 GetMacFromFIS TRUE
14
15 #Early builds may not want cewrts installed- set to False in that case
16 IncludeCertLogic TRUE
17 SeriesIdSupport FALSE
18 BlueToothSupport TRUE
19
20 MfgNumItems 4
21 MfgItems[0] CPU
22 MfgItems[1] AMP
23 MfgItems[2] WIFIMAC
24 MfgItems[3] WIFITYPE
25
26 #Append the OUI+product range to the next string to add new serial number range
27 SerialNumberFormats
28 #Uncomment the Sonos or IAC settings depending on where you are running. These are
29 #Cert Server values
30 #Sonos
31 #DestinationPort 443
32 #CertServer https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx
33 #DestinationAddress 10.253.0.3
34 #IAC
35 DestinationPort 8443
36 CertServer https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx
37 DestinationAddress 10.159.248.10
38
39 #uncomment out the appropriate path depending on the Apache installation
40 #ProductionUpdPath C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Hideout
41 ProductionUpdPath C:\program files\apache group\apache2\htdocs\ShipFirmware\Hideout
42 ModelSuffix -1-24.upd
43
44
45 <StationGlobals> Variable Value
46 ProductionDataFolder C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING
47 EngineeringDataFolder C:\Sonos Engineering Data

View File

@@ -0,0 +1,45 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"ALPINE"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"False"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"AMP"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Alpine"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Alpine"
ModelSuffix,"-1-25.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,49 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"BEACON"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want certs installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
BlueToothSupport,"True"
#Paramount and Beacon refuse to blink when stopped in U-Boot after Upgrade
BlinkingLedMsg,"False"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Beacon"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Beacon"
ModelSuffix,"-1-20.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,45 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"BOOTLEG"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want certs installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"7828CA0 7828CA1"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Bootleg"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Bootleg"
ModelSuffix,"-1-21.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,56 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"ELREY"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA AUDIOSA FA1"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
BlueToothSupport,"True"
#MfgNumItems,8
MfgNumItems,6
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"PWR"
MfgItems[3],"RADIO"
MfgItems[4],"CCI"
MfgItems[5],"CBI"
#MfgItems[6],"WIFIMAC"
#MfgItems[7],"WIFITYPE"
#Override forspecialty wipes. In Elrey P2A, we want wifi info left in jffs
#WipeCommand,"operation/wipejffs?test=rpt_elrey"
WhiteLedWait,55
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"949F3EC 949F3ED"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\ElRey"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\ElRey"
ModelSuffix,"-1-23.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,39 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"ENCORE"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
MfgNumItems,0
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"5CAAFD0"
RmaUpgrade,"True"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
#DestinationPort,"8443"
#CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Encore"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Encore"
ModelSuffix,"-1-13.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,49 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"HIDEOUT"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"True"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
BlueToothSupport,"False"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"RCA"
MfgItems[3],"PWR"
#MfgItems[4],"WIFIMAC"
#MfgItems[5],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"347E5C0"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Hideout"
ProductionUpdPath,"C:\Program Files\Apache Group\Apache2\htdocs\ShipFirmware\Hideout"
ModelSuffix,"-1-24.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,48 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"PARAMOUNT"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA PREBURNIN"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"False"
#Paramount and Beacon refuse to blink when stopped in U-Boot after Upgrade
BlinkingLedMsg,"False"
#Early builds may not want cewrts installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
MfgNumItems,4
MfgItems[0],"CPU"
MfgItems[1],"AMP"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,"949F3EB"
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
#DestinationPort,"443"
#CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.253.0.3"
#IAC
DestinationPort,"8443"
CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
#ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Paramount"
ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Paramount"
ModelSuffix,"-1-22.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,55 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"SOLBASE"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,"CPUSA"
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"False"
#Early builds may not want certs installed- set to False, in that case
IncludeCertLogic,"True"
SeriesIdSupport,"False"
#MfgNumItems,8
MfgNumItems,6
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"PWR"
MfgItems[3],"RADIO"
MfgItems[4],"CCI"
MfgItems[5],"CBI"
#MfgItems[6],"WIFIMAC"
#MfgItems[7],"WIFITYPE"
#Override forspecialty wipes. In Elrey P2A, we want wifi info left in jffs
#WipeCommand,"operation/wipejffs?test=rpt_elrey"
WhiteLedWait,35
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
DestinationPort,"443"
CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.253.0.3"
#IAC
#DestinationPort,"8443"
#CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Solbase"
#ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Solbase"
ModelSuffix,"-1-14.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.

View File

@@ -0,0 +1,49 @@
<Step Name>,Comp,Limits.High,Limits.Low
<Locals>,Variable Value
<FileGlobals>,Variable Value
ProductName,"TUPELO"
TestName,"UPGRADE"
TestNameForLog,"UPGRADE"
PreviousTestsRequired,""
SetUpForNextStation,1
#Not yet a working option
GetMacFromFIS,"False"
#Early builds may not want certs installed- set to False, in that case
IncludeCertLogic,"False"
SeriesIdSupport,"False"
BlueToothSupport,"False"
#Paramount and Beacon refuse to blink when stopped in U-Boot after Upgrade
BlinkingLedMsg,"False"
MfgNumItems,0
MfgItems[0],"CPU"
MfgItems[1],"SCI"
MfgItems[2],"WIFIMAC"
MfgItems[3],"WIFITYPE"
#Append the OUI+product range to the next string to add new serial number range
SerialNumberFormats,""
#Uncomment the Sonos or IAC settings, depending on where you are running. These are
#Cert Server values
#Sonos
DestinationPort,"443"
CertServer,"https://us-prod-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
DestinationAddress,"10.253.0.3"
#IAC
#DestinationPort,"8443"
#CertServer,"https://iacsms-certsys.sonos.com/CertServer/SecureBoot/SignerWs.asmx"
#DestinationAddress,"10.159.248.10"
#uncomment out the appropriate path depending on the Apache installation
ProductionUpdPath,"C:\program files (x86)\apache group\apache2\htdocs\ShipFirmware\Beacon"
#ProductionUpdPath,"C:\program files\apache group\apache2\htdocs\ShipFirmware\Beacon"
ModelSuffix,"-1-26.upd"
<StationGlobals>,Variable Value
ProductionDataFolder,"C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder,"C:\Sonos Engineering Data"
Can't render this file because it has a wrong number of fields in line 3.