Files
Labview-Program/Json Extract/data01/NG1235AAMM0001.20230623103343.json
2025-09-10 14:52:13 +08:00

189 lines
4.8 KiB
JSON

{
"ProductName": "GRAVITY",
"TestName": "AMPSA",
"Station": "P3-NTG1-SA-AMP",
"Version": "1.0.0.0",
"SN": "NG1235AAMM0001",
"Result": "PASS",
"Duration": 103.10,
"EndTime": "2023-06-23 10:33:43",
"TestSteps": [
{
"Name": "Test socket Index",
"Type": "StringValueTest",
"Result": "PASS",
"Value": "1",
"Expected": "1",
"Duration": 0.00
},
{
"Name": "PS-Measure Working Current",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 0.01,
"Value": 0.0981,
"Max": 0.2,
"Duration": 0.12
},
{
"Name": "FCB-Check No AMP Fault",
"Type": "PassFailTest",
"Result": "PASS",
"Duration": 0.03
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "RMS Level 60Hz_1",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 7.2,
"Value": 7.6408,
"Max": 8.9,
"Duration": 0.00
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "RMS Level 60Hz_2",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 7.2,
"Value": 7.6027,
"Max": 8.9,
"Duration": 0.00
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "Gain 60Hz_1",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 19,
"Value": 19.601,
"Max": 21,
"Duration": 0.00
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "Gain 60Hz_2",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 19,
"Value": 19.558,
"Max": 21,
"Duration": 0.00
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "THD+N Ratio 60Hz_1",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 0.001,
"Value": 0.0063888,
"Max": 0.05,
"Duration": 0.00
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "THD+N Ratio 60Hz_2",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 0.001,
"Value": 0.0082733,
"Max": 0.05,
"Duration": 0.00
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "Signal to Noise Ratio 60Hz_1",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 75,
"Value": 98.423,
"Max": 105,
"Duration": 0.00
},
{
"Name": "Load Result",
"Type": "PassFailTest",
"Result": "SKIPPED",
"Duration": 0.00
},
{
"Name": "Signal to Noise Ratio 60Hz_2",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 75,
"Value": 98.189,
"Max": 105,
"Duration": 0.00
},
{
"Name": "AP: Measurements Result",
"Type": "PassFailTest",
"Result": "PASS",
"Duration": 0.00
},
{
"Name": "RMS Level 60Hz_1 with AMP mute",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 0,
"Value": 1.1387E-5,
"Max": 0.001,
"Duration": 0.00
},
{
"Name": "RMS Level 60Hz_2 with AMP mute",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 0,
"Value": 8.8763E-6,
"Max": 0.001,
"Duration": 0.00
},
{
"Name": "PS-Measure Discharged Voltage",
"Type": "NumericLimitTest",
"Result": "PASS",
"Min": 0,
"Value": 0.346,
"Max": 1,
"Duration": 0.11
}
]
}