HOW TO BUILD THE RUNTIME ENGINES INSTALLER PACKAGE
updated 03-May-2018 J. Czapski
1. Confirm that you have the result-processing plugins SonosMFG_ProdResultsJSON.seq and SonosMFG_ProdResultsXML.seq in your local Teststand Public directory at:
C:\Users\Public\Documents\National Instruments\TestStand 2016 (32-bit)\Components\Models\ModelPlugins
and those sequences' step VIs and subVIs at:
C:\Users\Public\Documents\National Instruments\TestStand 2016 (32-bit)\Components\Models\ModelPlugins\VIs
2. Confirm that you have 'upload json test results to pipeline.exe' and its two INI files at:
C:\Sonos\test results uploader
3. Open in Teststand the TS workspace file 'Runtime Engines Installer.tsw'.
4. In Teststand, go to View > Station Globals and set the values that you want the station to have for ProductionDataFolder and EngineeringDataFolder, and then Save Station Globals. ProductionDataFolder can specify multiple folders separated by semicolon (;). For example:
ProductionDataFolder = "C:\IDU_MFG_OUTGOING;C:\IAC_OUTGOING"
EngineeringDataFolder = "C:\Test_Engineering"
5. Go to Configure > Station Options and Enable Tracing with fastest speed, and Allow Tracing into Setup/Cleanup but do not allow tracing into any other structures. Set On Run-Time Error = Run Cleanup. Uncheck 'Use Computer Name for Station ID' and set Station ID to ID_NOT_SET. Uncheck all the user-login boxes including Check User Privileges, Require User Login, Automatically Login Windows System User, and Login On Start.
6. Go to Configure > Adapters and Configure the Labview Adapter to use Labview Run-Time instead of Labview development system.
7. Go to Configure > Result Processing and Enable the output plugin SonosMFG_ProdResultsJSON but disable the plugins Report and SonosMFG_ProdResultsXML. Configure options correctly for each of those three plugins. Make sure that Report is set to Specify Path By Expression and the expression is set to StationGlobals.EngineeringDataFolder + "\\$(ClientFileName) $(UUT) $(FileDate) $(FileTime)$(Unique).$(FileExtension)". For the Batch File Path expression, use $(Batch) in place of $(UUT).
8. Go to Tools > Deploy Teststand System and Load 'Runtime Engines.tsd'. Go through the tabs in order and make sure that the build destination folders (Location Of Depoyable Image and Installer Directory) are correct for your development machine. You should not have to change any of the other settings. Finally, go to the Build Status tab and click the Build button.